ÃÛÌÒÊÓƵ

Upgrade Your Meridian Precision ÃÛÌÒÊÓƵ TimeBase

Meridian Precision ÃÛÌÒÊÓƵ TimeBase

Free Software Upgrades

We provide free software upgrades for our products The software available on this page is for the Meridian Precision ÃÛÌÒÊÓƵ TimeBase. Here are the latest binary image files:

Linux Subsystem (Root File System)
What is the number of your current software? You need to know this number in order to get the correct binary image for upgrading the Linux Subsystem of your Meridian. To get the software number type command: "gsysversion". You will see the software number displayed like this:
Ìý
Meridian ÃÛÌÒÊÓƵ 6010-004x-000
Ìý
Click here if x=2 (software number is 6010-0042-000)
Click here if x=4 (software number is 6010-0044-000)
Ìý
ÃÛÌÒÊÓƵ Subsystem
Current revision level is v5.11.
You may not need to upgrade. Check the history of software changes first.
If you do decide to upgrade the ÃÛÌÒÊÓƵÌýSubsystem then be sure to also upgrade the Linux Subsystem.
ClickÌýhereÌýto download ÃÛÌÒÊÓƵ Subsystem 6010-0020-000 v5.11.

Ìý

Upgrade Instructions

For complete instructions, please refer to "Appendix B - Upgrading the Firmware" of your User Manual.Ìý If you want to download the latest manual clickÌýhere.

If you have any problems with the upgrade please contact customer support byÌýemailÌýor phone: 1-877-749-3878.

Ìý

History of Software Changes

Linux Subsystem (Root File System) — Software Part Numbers 6010-0042-000 and 6010-0044-000

Version Changes
5.70 Patches applied to correct Shellshock vulnerabilities.Ìý Please see Field Service BulletinÌýFSB140926-02.
RECOMMENDATION: Please upgrade unless you have secured the network port on your Meridian per the instructions in the Bulletin.

NOTE 1:Ìý If you are upgrading and the current version in your unit is 5.50 or less, then pleaseÌýread this first.
NOTE 2:Ìý IPv6 users - If you want the IPv6-capable kernel then clickÌýhereÌýto download.Ìý For information on IPv6 capabilities read theseÌýrelease notes.

5.67 Minor bugs fixed in the PTP option.
RECOMMENDATION: No need to upgrade unless you have the PTP Option.
5.64 1.ÌýFixed bug where sometimes, at first power-up after being shipped from factory, the NTP daemon would take a longer time than normal to indicate lock status.
2.ÌýFixed bug in HTTP interface where it reports NTP Stratum 16 when the actual Stratum is any level greater than 2.
3.ÌýFixed bug introduced at version 5.60 where the ntp daemon continues to serve Stratum 1 time after receiver subsystem goes unlocked for an extended period.
4.ÌýDual power supply option: Added ability to inhibit Alarm LED and Alarm Open-Collector Output from going active if one of the power supplies fails or is not powered.Ìý New commands are PWRFLTMASK and SETPWRFLTMASK.
RECOMMENDATION: No need to upgrade unless one of these items is important to you.
5.63 Fixed minor bug - erroneous SNMP traps when NTP is flooded with packets.
RECOMMENDATION: No need to upgrade unless this is important to you.
5.62 1.ÌýPTPv2 Option: Removed PTP "Port State = Listen" which could prevent the clock from becoming "Port State = Master".
2.ÌýFixed polling fault that may occur when the unit is powered up the very first time only.
RECOMMENDATION: Upgrade if one of the above items is important to you.
5.61 1.ÌýPTP Option: Fixed mishandling of packet sequence numbers when packets are dropped.
2.ÌýFixed bug where password is displayed when upgrading firmware using the Web Interface.
3.ÌýFixed bug that prevents you from upgrading firmware using the Web Interface and the "Upgrade From Local File" option.Ìý Because of this flaw in your current version you must upgrade using the Web Interface and the "Upgrade From FTP Server" option, or by using the command line interface.
4.ÌýFixed bug introduced with change to NTP distribution 4.2.6p3 where ntpd would terminate if user did not configure network settings.
RECOMMENDATION: Upgrade if you have the PTP Option or use the Web Interface.
5.60 1.ÌýUpdated NTP distribution version to 4.2.6p3 which solves the vulnerability below (item #5) and also improves timing jitter performance.
2.ÌýAdded version 2 for PTP/IEEE-1588.Ìý This only pertains to those who have purchased the PTP Option.
3.ÌýFixed network domain name bug for domains with more than one '.' in them.
4.ÌýFixed rare Secure Shell permissions bug.
5.ÌýWorkaround for ntpq/ntpdc remote query vulnerability.Ìý Did this even though the updated NTP distribution should solve the problem.
RECOMMENDATION: Upgrade if one of the above items is important to you.
5.50 1.ÌýAdded capability for PTP/IEEE-1588 Option that allows setting of multicast time-to-live (ttl) variable.
2.ÌýAdded capability to edit and view the Domain Name Server (DNS) via the front-panel keypad/display.
3.ÌýFixed a bug related to erroneous SNMP FaultStatus2 traps.
4.ÌýFixed a bug in the "gpsrefpos" command which inhibited showing reference position in "unknown" and "dynamic" modes.
5.ÌýFixed a bug in the SNMP MIB related to the plug-in options.
6.ÌýAdded Web Interface (HTTPS) for monitoring status of all functions and for upgrading software.Ìý This new capability is only for units with Software Number 6010-0044-000.Ìý The Web Interface is disabled for units with Software Number 6010-0042-000 (because these are older units and the required hardware is not available).
RECOMMENDATION: Upgrade if one of the above items is important to you.
5.11 Fixed a bug related to the gsysuser login.Ìý If you are having trouble logging in to your unit then upgrading your software will not correct the problem.Ìý Please see thisÌýField Service Bulletin.
RECOMMENDATION: No need to upgrade.
5.10 New option added to the product line: Precision Time Protocol (PTP/IEEE-1588).
RECOMMENDATION: No need to upgrade.
5.00 Added software support for new features: Telecom Clock Output Module and Dual Power Supplies.
RECOMMENDATION: No need to upgrade.
4.00 1.ÌýModified the start-up sequence to eliminate the need for operator intervention in order to show the time on the display.Ìý Now the unit will go to the time display 30 seconds after the startup sequence has finished.
2.ÌýAdded additional format selections to the Serial Time Output Option.
3.ÌýChanged TFOM value to be in the range of 9-3 (was 9-4).Ìý A TFOM of 3 indicates synchronization accuracy to within 100 nanoseconds.
4.ÌýAdded CRC checking on the time information going from the ÃÛÌÒÊÓƵ Subsystem to the Linux Subsystem.Ìý This will further bulletproof the timekeeping ability of the product and prevent any possible time jumps in the rare case (seen only once) of a hardware glitch on the circuit board.
RECOMMENDATION: Upgrade if you would like the features listed in #2 or #4.
3.02 1.ÌýTo enhance SSH security, the default was changed from accepting versions 1 and 2 protocol connections to only accepting version 2 protocol connection.Ìý Version 1 is considered insecure.
2.ÌýFixed a bug wherein the NTP Server continued to serve time for too long after loss-of-lock to ÃÛÌÒÊÓƵ synchronization signal.
RECOMMENDATION: Please upgrade.
3.01 1.ÌýFixed a bug related to the AM/PM local time display.
2.ÌýAdded 0.1 meter resolution capability to the console "setgpsrefpos" script.
RECOMMENDATION: Upgrade if you use local time 12-hour mode for your display.
3.00 1.ÌýAdded ability to change TFOM level at which alarm occurs.
2.ÌýAdded ability to set optional Serial Time Output format via front-panel keypad/display.
3.ÌýAdded ability to mask off certain alarms - the Antenna Fault and the Signal Loss Fault.
4.ÌýAdded more selections for the optional Programmable TTL Output.
5.ÌýAdded alternative Time Display that shows the time with Day-Of-Year as: DOY:HH:MM:SS.
6.ÌýFixed a bug related to unprivileged user in cntpstat/gntpstat reporting.
RECOMMENDATION: Upgrade if you care about one of the items above.
2.63 Added capability to discipline new oscillator type.Ìý Irrelevant for previously shipped products.
RECOMMENDATION: No need to upgrade.
2.62 1.ÌýFixed a bug related to changing DST information via the front-panel display.
2.ÌýFixed a bug when entering positive time zone offsets via console port command "timemodeconfig".
RECOMMENDATION: Upgrade if you are in a positive time zone (east of Greenwich Mean Time) or you use the Daylight Savings Time (DST) feature.
2.61 Changes not relevant to the Meridian.
RECOMMENDATION: No need to upgrade.
2.60 Major upgrade with updated versions of all applications, utilities and shared libraries typically installed in an embedded Linux-based system.Ìý Please click hereÌýfor IMPORTANT information:
RECOMMENDATION: Please upgrade.
NOTE: This software release is IPv6-capable.Ìý IPv6 is in the experimental stage but some of our customers want it now.Ìý In order to enable IPv6 operation you must perform a second upgrade operation to replace your IPV4-only kernel.Ìý If you want IPv6 operation then clickÌýhereÌýto download the IPv6-capable Linux kernel.
2.05 Added capability to discipline new oscillator type.Ìý Irrelevant for current products.
RECOMMENDATION: No need to upgrade.
2.04 Added capability to discipline new oscillator type.Ìý Irrelevant for current products.
RECOMMENDATION: No need to upgrade.
2.03 Improved the ÃÛÌÒÊÓƵ receiver status and oscillator control status displays.
RECOMMENDATION: Upgrade if you want the improved displays.
2.02 Fixed minor bug that displayed the wrong filesystem partition.
RECOMMENDATION: No need to upgrade.
2.01 Changes include:
1.ÌýModified status command (gpsstat) to show 20-bit DAC value instead of 16-bits.
2.ÌýAdded variables to SNMP MIB.
RECOMMENDATION: Upgrade if you care about one of the items above.
2.00 First release for Meridian.
This release was an integration of Time Server and Time & Frequency products into the same firmware image with automatic boot time configuration of the model and receiver type.
RECOMMENDATION: No need to upgrade.

Ìý

ÃÛÌÒÊÓƵ Subsystem — Software Part Number 6010-0020-000

Version Changes
5.11 Changes include:
1.Ìý Improved spoofing & error protection on data received from ÃÛÌÒÊÓƵ.
2.Ìý Corrected bug where leap second does not occur properly unless the unit is locked to a ÃÛÌÒÊÓƵ signal at UTC midnight.
RECOMMENDATION: ÃÛÌÒÊÓƵ users please upgrade.Ìý If the Linux Subsystem in your Meridian is prior to version 5.00, you must also upgrade the Linux Subsystem.
5.10 Changes include:
1.Ìý Corrected week rollover problem caused by ÃÛÌÒÊÓƵ receiver from 3rd-party vendor.Ìý Problem began at UTC midnight on Feb 14, 2016.Ìý After upgrading to v5.10, this product should not be affected by another ÃÛÌÒÊÓƵ week rollover until the year 2035.Ìý For details, read thisÌýField Service Bulletin.
2.Ìý Added error checking on UTC offset parameters received from ÃÛÌÒÊÓƵ receiver.
RECOMMENDATION: ÃÛÌÒÊÓƵ users please upgrade.
5.09 Corrected TFOM changing too quickly for some ÃÛÌÒÊÓƵ antenna installations.Ìý TFOM would quickly change from 3 to 4 and back again, which caused unwanted SNMP trap notifications.
RECOMMENDATION: Upgrade if you have experienced this problem.
5.08 Added support for dual power supplies.
RECOMMENDATION: No need to upgrade unless your Meridian has dual power supplies.
5.07 Changes not relevant to the Meridian ÃÛÌÒÊÓƵ.
RECOMMENDATION: No need to upgrade.
5.06 Fixed a bug related to backplane output - 1PPS falling edge on-time.
RECOMMENDATION: No need to upgrade unless you use 1PPS falling edge.
5.05 Corrected minor bug that occurred only when 4 Telecom Clock Option Boards are installed.
RECOMMENDATION: No need to upgrade.
5.04 1.ÌýCorrected identification of dual power supplies.
2.ÌýCorrected bug that wore out FLASH memory chips on ÃÛÌÒÊÓƵ units operating for long periods of time without an antenna.Ìý See thisÌýField Service Bulletin.
RECOMMENDATION: ÃÛÌÒÊÓƵ users please upgrade.
5.03 Corrected bug introduced in version 5.00 (ÃÛÌÒÊÓƵ only).
RECOMMENDATION: ÃÛÌÒÊÓƵ users please upgrade.
5.02 Improved IRIG-B time code generation.Ìý
RECOMMENDATION: No need to upgrade unless the time code reader you are using is having trouble reading the IRIG. (Rare problem - seen only once.)
5.01 Continued software support for new feature: Telecom Clock Output Module.
RECOMMENDATION: No need to upgrade.
5.00 1.ÌýAdded software support for new features: Telecom Clock Output Module and Dual Power Supplies.
2.ÌýCorrected rare bug in ÃÛÌÒÊÓƵ leap second processing.
RECOMMENDATION: ÃÛÌÒÊÓƵ users upgrade before next leap second occurrence.
4.00 1.ÌýAdded additional format selections to the Serial Time Output Option.
2.ÌýChanged TFOM value for ÃÛÌÒÊÓƵ model to be in the range of 9-3 (was 9-4).Ìý Note: TFOM is usually irrelevant for time server customers.
3.ÌýCorrected bug in the IRIGB-120/IEEE1344 output.
4.ÌýAdded CRC checking on the time information going from the ÃÛÌÒÊÓƵ Subsystem to the Linux Subsystem.Ìý This will further bulletproof the timekeeping ability of the product and prevent any possible time jumps in the rare case (seen only once) of a hardware glitch on the circuit board.
RECOMMENDATION: Upgrade if you are using the optional IRIGB-120/IEEE1344 output.
3.03 Added NMEA0183 format to the Serial Time Output option.
RECOMMENDATION: No need to upgrade.
3.02 Change not relevant to the Meridian.
RECOMMENDATION: No need to upgrade.
3.01 Added software to work with new version of hardware circuit board.Ìý Irrelevant for previously shipped products.
RECOMMENDATION: No need to upgrade.
3.00 No change.Ìý Version bumped to maintain synchronization with Linux Subsystem version.
RECOMMENDATION: No need to upgrade.
2.13 Added capability to discipline new oscillator type.Ìý Irrelevant for previously shipped products.
RECOMMENDATION: No need to upgrade.
2.12 Test routine added for factory manufacturing.Ìý Irrelevant for customer.
RECOMMENDATION: No need to upgrade.
2.11 Added new string format selections for optional Serial Time Output.
RECOMMENDATION: No need to upgrade.
2.10 Test routine added for factory manufacturing.Ìý Irrelevant for customer.
RECOMMENDATION: No need to upgrade.
2.09 Changed time code format selection list.
RECOMMENDATION: No need to upgrade.
2.08 Fixed a minor bug in the time display when the timemode was set for ÃÛÌÒÊÓƵ.
RECOMMENDATION: Upgrade if you are using ÃÛÌÒÊÓƵ timemode.
2.07 Changes include:
1.ÌýModified ÃÛÌÒÊÓƵ calibration delay based on data from NIST testing.Ìý This causes an 86 nanosecond advance in time relative to previous software versions.
2.ÌýCorrected extremely rare bug for ÃÛÌÒÊÓƵ units that occurred only in very high interference environments.
RECOMMENDATION: ÃÛÌÒÊÓƵ users please upgrade.
2.06 Added capability to discipline new oscillator type.Ìý Irrelevant for current products.
RECOMMENDATION: No need to upgrade.
2.05 Added capability to discipline new oscillator type.Ìý Irrelevant for current products.
RECOMMENDATION: No need to upgrade.
2.04 Modified oscillator regression behavior.Ìý
RECOMMENDATION: No need to upgrade.
2.03 Added capability to discipline new oscillator type.Ìý Irrelevant for current products.
RECOMMENDATION: No need to upgrade.
2.02 First release for Meridian.
RECOMMENDATION: No need to upgrade.

Ìý